Economizer Installation Wiring for Residential Package Units

Goodman has recently released Service Bulletin SP-038 Rev. 1 regarding economizer installation wiring for residential package units.  The purpose of this bulletin is to provide instructions for the installation of an economizer on “H” and “M” Series residential package units that do not have a factory installed economizer wiring harness.

Continue reading

Economizer Installation Wiring for Residential Package Units

Goodman recently issued Service Bulletin SP-038 providing instructions for the installation of an economizer on “M” Series residential package units that do not have a factory installed economizer wiring harness.

From Goodman:

The DP14GM24 – 48 and A/GPG1424 – 48 units have single-stage compressors and use a PCBAG123 single-stage control board. This board does not have an economizer wiring harness connection. Part # 0259G00214 (economizer wiring harness) would be used to connect from the control board and thermostat to the economizer 9-pin connector (see instructions below).
Note: Part # 0259G00214 is factory installed in the DP14GM48 and A/GPG1448 units, but is not on the 2.0 – 3.5 ton 14 SEER gas package models.

To install an economizer on the “M” series package cooling unit use economizer wiring harness (Part # 0259G00213) and on the “M” series package heat pumps models use economizer wiring harness (Part # 0259G00215) to connect from the control board and thermostat to the economizer 9-pin connector (see instructions below).

Gas Package Units (Utilizes harness connector Part # 0259G00214):
1. Connect yellow wire from pin #2 to the Y connection (yellow wire) from thermostat.
2. Connect yellow wire from pin #4 to yellow wire in unit control box (this wire is connected to pin 11 of the 12-pin connector on the control board).
3. Connect blue wire from harness (pin #5) to 24V Common (blue common wire) on unit.
4. Connect green wire from harness (pin #6) to ECON spade on control board.
5. Connect red wire from harness (pin #9) to R terminal (red wire) on transformer.

Capture1

Cooling Package Units (Utilizes harness connector Part # 0259G00213):
1. Connect yellow wire from pin #2 to the Y connection (yellow wire) from thermostat.
2. Connect yellow wire from pin #4 to Y connection (yellow wire) on unit.
3. Connect blue wire from harness (pin #5) to 24V Common connection (blue wires) on LVTB (low voltage terminal block) or C for unit and thermostat.
4. Connect green wire from harness (pin #6) to G connection (green wire) for unit and thermostat.
5. Connect red wire from harness (pin #9) to R connection (red wire) for unit and thermostat.

Capture2

Heat Pump Package Units (Utilizes harness connector Part # 0259G00215):
1. Connect yellow wire from pin # 2 to the Y connection (yellow wire) from thermostat.
2. Connect yellow wire from pin # 4 to Y connection (yellow wire) on unit.
3. Connect blue wire from harness (pin #5) to 24V Common connection (blue wires) on LVTB (low voltage terminal block) or C for unit and thermostat.
4. Connect green wire from harness (pin #6) to G connection (green wire) for unit and G connection for thermostat.
5. Connect orange wire from harness (pin #8) to O connection (orange wire) for unit and O connection for thermostat.
6. Connect red wire from harness (pin #9) to R connection (red wire) for unit and R connection for thermostat.

Capture3